Fanuc Power Mate i-D/H Maintenance Manual

B63175EN/03
G. MAINTENANCE USING A NOTEBOOK
PERSONAL COMPUTER
APPENDIX
563
The Power Mate i can be maintained using a notebook personal computer
connected with an RS232C cable.
(1)DPL/MDI operation package
The DPL/MDI operation package can modify programs and set
parameters.
(2)FAPT LADDER II
FAPT LADDER II can edit ladder programs online and display
diagnostic data.
How to use the DPL/MDI operation package is described below. For
details of FAPT LADDER II, refer to the related PMC manual.
The Power Mate i can be connected to a personal computer using an
RS232C cable to perform the following maintenance, display, and
setting operations.
f Boot system operations
(executable program to be used:
BOOTINIT.EXE)
D SYSTEM DATA LOADING
D SYSTEM DATA CHECK
D SYSTEM DATA DELETE
D SYSTEM DATA SAVE
D SRAM DATA BACKUP
D MEMORY CARD FILE DELETE
D MEMORY CARD FORMAT
D LOAD BASIC SYSTEM
f INIT operations
(executable program to be used: BOOTINIT.EXE)
D MEMORY ALL CLEAR
D MEMORY CLEAR (PARAMETER,OFFSET)
D MEMORY CLEAR (ALL PROGRAM)
D MEMORY CLEAR (PMC PARAMETER)
D MEMORY CLEAR (PMC LADDER)
D IGNORE OVER TRAVEL ALARM
D START WITHOUT LADDER
D C LANGUAGE EXECUTOR (MAKE VOID CEXEC)
f Operations during system operation
(executable program to be used:
DPLMDI.EXE)
D Displaying the current position
D Registering, editing, deleting, and checking CNC programs
D Setting parameters and pitch error compensation
D Displaying diagnostic information
D Displaying alarm messages
D Displaying and setting the PMC status
D Displaying system alarms
D Transferring and printing files (CNC programs, CNC
parameters, tool offset values, pitch error compensation, and
macro variables)
G.1
OVERVIEW
D Preface