Fanuc Power Mate i-D/H Maintenance Manual

B63175EN/03
G. MAINTENANCE USING A NOTEBOOK
PERSONAL COMPUTER
APPENDIX
599
Press
F3
MEN
VAR
. The offset screen, setting screen, and custom macro
variable screen alternately appear. Select the custom macro
variable screen.
1 Move the cursor to the position of the number of a macro variable
to be changed as follows:
1) Cursor key
2) Press
F6
&@
No.
. # is displayed following >.
>#
Then, enter a macro variable number.
Press
Enter
. The cursor moves to the target number position.
When this method is used, the cursor is always displayed on the
first line.
2 The following three methods are available according to the setting.
1) Setting a macro variable value
Key in a new value, then press
Enter
. The new macro variable
value is input and displayed.
2) Setting coordinates for a variable
Press the X key. The workpiece coordinates are displayed.
Press
Enter
. The workpiece coordinates are input for the macro
variable and are displayed.
G.5.2.5
Custom macro variable
D Display operation
D Rewriting procedure