Fanuc Power Mate i-D/H Maintenance Manual

G. MAINTENANCE USING A NOTEBOOK
PERSONAL COMPUTER
B63175EN/03
APPENDIX
602
(1)Parameter (input)
1 Press the EMERGENCY STOP button on the machine.
2 Select the parameter screen.
Press
F4
DGN
PRM
. The parameter screen, diagnosis screen, and pitch
error compensation screen alternately appear. Select the parameter
screen.
3 When parameters are stored in a file in a device, perform file
heading as required.
4 Press
F7
RD
to input the parameters.
During input, RD is displayed as follows:
> RD
(2)Parameter (output)
1 Select the EDIT mode.
2 Select the parameter screen.
Press
F4
DGN
PRM
. The parameter screen, diagnosis screen, and pitch
error compensation screen alternately appear. Select the parameter
screen.
3 Press
F8
WRT
to output the parameters.
During output, WRT is displayed as follows:
> WRT
G.5.2.7
Pitch error
compensation