Fanuc Power Mate i-D/H Maintenance Manual

B63175EN/03
G. MAINTENANCE USING A NOTEBOOK
PERSONAL COMPUTER
APPENDIX
603
Press
F4
DGN
PRM
. The parameter screen, diagnosis screen, and pitch
error compensation screen alternately appear. Select the pitch error
compensation screen.
1 Move the cursor to the position of the number of a pitch error
compensation value to be changed as follows:
1) Cursor key
2) Press
F6
&@
No.
. P is displayed following >.
>P
Then, enter a pitch error compensation number.
Press
Enter
. The cursor moves to the target number position.
When this method is used, the cursor is always displayed on the
first line.
2 Key in a new value, then press
Enter
. The new pitch error
compensation value is input and displayed.
(1)Pitch error compensation (input)
1 Select the EDIT mode.
2 Select the pitch error compensation screen.
Press
F4
DGN
PRM
. The parameter screen, diagnosis screen, and pitch
error compensation screen alternately appear. Select the pitch error
compensation screen.
3 When pitch error compensation values are stored in a file in a
device, perform file heading as required.
4 Press
F7
RD
to input the pitch error compensation values.
During input, RD is displayed as follows:
> RD
(2)Pitch error compensation (output)
1 Select the EDIT mode.
2 Select the pitch error compensation screen.
Press
F4
DGN
PRM
. The parameter screen, diagnosis screen, and pitch
error compensation screen alternately appear. Select the pitch error
compensation screen.
3 Press
F8
WRT
to output the pitch error compensation values.
During output, WRT is displayed as follows:
> WRT
D Display operation
D Rewriting procedure