Fanuc Power Mate i-D/H Maintenance Manual

B63175EN/03
G. MAINTENANCE USING A NOTEBOOK
PERSONAL COMPUTER
APPENDIX
607
When PMC data is displayed, pressing
.
changes the data type
for display and setting.
Each time
.
is pressed, the data type changes in the following
order:
Onebyte bit Onebyte
decimal
Twobyte
decimal
Fourbyte
decimal
CAUTION
The current data type is onebyte bit or decimal when the
difference between adjacent numbers is 1, twobyte
decimal when it is 2, or fourbyte decimal when it is 4.
1 Set DWE to 1 on the setting screen.
2 Press the key of a PMC address to be displayed.
3 Press the number of the PMC address to be displayed.
4 Press
Enter
to display the PMC data.
5 Press
.
to select a data type.
6 Press
Enter
to input and display the data value.
7 After setting and checking all PMC data, display the setting screen
and set DWE to 0 again.
Data in the following areas can be displayed and set:
X0000 to 0127, X1000 to 1063
Y0000 to 0127, Y1000 to 1063
G0000 to 0511
F0000 to 0511
A0000 to 0024
R0000 to 0999, R9000 to 9117
T0000 to 0079
K0000 to 0019
C0000 to 0079
D0000 to 1859
D Changing the data type