Fanuc Power Mate i-D/H Maintenance Manual

G. MAINTENANCE USING A NOTEBOOK
PERSONAL COMPUTER
B63175EN/03
APPENDIX
614
The following parameters can be set for items related to use of the
DPL/MDI operation package.
Explanation of parameter
#7
370
#6 #5 #4 #3 #2 #1 #0
PCID1
Number
Data
[Data type] Bit
PCID1 Specifies whether to display absolute and machine coordinates on the
CRT display when the DPL/MDI operation package is connected.
0 : Displays absolute and machine coordinates. (Fullsize characters are
displayed.)
1 : Displays only absolute coordinates. (Triplesize characters are
displayed.)
NOTE
When the number of controlled axes is 7 or more, the screen
displayed with this parameter set to 0 is also displayed with
this parameter set to 1.
Explanation of parameter
0380 PCTCNT
Number Data
PCNTCNT Interval for sending a communication establishment request packet for
the DPL/MDI operation package
[Data type] Word
[Unit of data] msec
[Valid data range] 1000 to 10000 (internal setting when a value of 0 or no value is set: 3000)
Explanation of parameter
0381 PCTCNF
Number Data
PCTCNF Interval for sending a connection confirmation packet for the DPL/MDI
operation package
[Data type] Word
[Unit of data] msec
[Valid data range] 1000 to 10000 (internal setting when a value of 0 or no value is set: 5000)
G.6
RELATED
PARAMETERS