Fanuc Power Mate i-D/H Maintenance Manual

B63175EN/03
G. MAINTENANCE USING A NOTEBOOK
PERSONAL COMPUTER
APPENDIX
617
SRAM DATA BACKUP ERROR
HIT <ENTER>
An attempt to write backup data onto a memory card failed.
Check that the memory card status is normal.
S
SRAM DATA RESTORE ERROR
HIT <ENTER>
Backup data could not be read from a memory card successfully.
The memory card file is invalid. Check that the memory card status is normal.
SRAM 256K.*
NOT FOUND
System data file SRAM256A.FDB is not found on the memory card.
Use a memory card containing SRAM256A.FDB.
The following describes the explanation of and the action to be taken for
each error message output on the popup window by application software
products of the DPL/MDI operation package BOOTINIT.EXE and
DPLMDI.EXE on the personal computer.
In the Power Mate side, BOOT SYSTEM is started now.
DPLMDI.EXE was started before startup of the system.
Terminate DPLMDI.EXE, then start up the system.
Then, restart DPLMDI.EXE.
Alternatively, execute BOOTINIT.EXE before
poweron to use the boot system.
In the Power Mate side, INIT SYSTEM is started now.
DPLMDI.EXE was started before startup of the system.
Terminate DPLMDI.EXE, then start up the system.
Then, restart DPLMDI.EXE.
Alternatively, execute BOOTINIT.EXE before
poweron to use the boot system.
In the Power Mate side, DPL/MDI SYSTEM is started now.
BOOTINIT.EXE was started after startup of the system.
To operate the boot system, start up BOOTINIT.EXE
before turning the power to Power Mate on.
Control code error (ERROR:CODE***)
Communication error. Restart up DPLMDI.EXE or
BOOTINIT.EXE.
Function code error (ERROR:CODE***)
Communication error. Restart up DPLMDI.EXE or
BOOTINIT.EXE.
The end command was not issued from NC.
The exit process is abnormal. There is a possibility
of a abnormal communication.
The Power Mate i does not recognize the end code.
Reexecute DPLMDI.EXE. If communication is not
restarted normally, the Power Mate i is in an error state.
Check the LED display and take appropriate actions.
The packet from the Power Mate does not reach.
There is possibility that the communication has
been disconnected.
Terminate this application. Then resume it.
No interface packet is sent from the Power Mate i. The
Power Mate i may disconnect communication. Restart
the application.
(The application is automatically connected.)
The break signal has been detected.
CD signal check error has been detected!
CTS signal check error has been detected!
The error occurred when DCB was acquired.
DSR signal check error has been detected!
Framing error has been detected!
Overrun error has been detected!
Receive buffer has overflowed!
Parity error has been detected!
Transmitting buffer has overflowed!
Unidentified error or event has been detected!
Communication process is abnormal! Check the
connection and the rotary switch setting!
An error occurred. The cause is an RS232C cable
specification, connection error, noise, or another
environment error. Check the environment such as
cable connection and noise.
A system alarm may be displayed on the alarm display of the DPL/MDI
window during startup of the system. For details of the alarm number and
system alarm, see Appendix A.
D BOOTINIT.EXE/
DPLMDI.EXE messages
and actions to be taken
D CNC system error codes
and alarms

Leave a Reply

Your email address will not be published. Required fields are marked *