Fanuc Power Mate i-D/H Maintenance Manual

B63175EN/03
H. FSSB STARTUP PROCEDURE/
MATERIALS
APPENDIX
619
With a system that uses the FSSB, the parameters below need to be set for
axis setting. (Set other parameters as usually done.)
D No. 1023
D No. 1905
D No. 1910 to 1919
D No. 1936, 1937
For setting of these parameters, three methods are available.
1. Automatic setting
By entering data including the relationship between axes and
amplifiers on the FSSB setting screen, a calculation for axis setting is
made automatically, and parameter Nos. 1023, 1905, 1910 through
1919, 1936, and 1937 are automatically set.
This setting is used with Power Mate iD 2path control.
2. Manual setting 2
Enter desired values directly in all of parameter Nos. 1023, 1905, 1910
through 1919, 1936, and 1937.
Before setting the parameters, fully understand the functions of the
parameters.
3. Manual setting 1(NOTE)
Based on the setting of No. 1023, default axis setting is performed.
Parameter Nos. 1905, 1910 through 1919, 1936, and 1937 need not be
set. Automatic setting is not performed.
NOTE
With manual setting 1, usable functions are limited. So,
when starting up the FSSB, use automatic setting or manual
setting 2 whenever possible.
H.1
OVERVIEW

Leave a Reply

Your email address will not be published. Required fields are marked *