Fanuc Power Mate i-D/H Maintenance Manual

H. FSSB STARTUP PROCEDURE/
MATERIALS
B63175EN/03
APPENDIX
632
1936 Connector number for the first pulse module
PRM
1937 Connector number for the second pulse module
PRM
[Data type] Byte axis
[Valid data range] 0 to 7
When using a pulse module, set a value obtained by subtracting 1 from
the pulse module connector number for each axis. That is, for connector
numbers 1 to 8, set the values 0 to 7. Moreover, set bits 6 and 7 of
parameter No. 1905. Set 0 for an axis for which no pulse module is used.
The user can freely determine which connector to use for which axis. Use
connector numbers, starting with younger numbers. For example,
connector number 4 cannot be used without using connector number 3.
Example:
Con-
trolled
axis
First con-
nector
number
Second
connector
number
No.1936 No.1937 No.1905
(#7,#6)
X 1 Not used 0 0 0,1
Y Not used 2 0 1 1,0
Z Not used 1 0 0 1,0
A Not used Not used 0 0 0,0
B 2 Not used 1 0 0,1
C Not used 3 0 2 1,0
These parameters are automatically set by data input on the FSSB setting
screen when the FSSB setting mode is the automatic setting mode (when
bit 0 of parameter No. 1902 = 0). When the manual setting 2 mode is used
(when bit 0 of parameter No. 1902 = 1), be sure to enter necessary data
directly.