Fanuc Power Mate i-D/H Maintenance Manual

B63175EN/03
H. FSSB STARTUP PROCEDURE/
MATERIALS
APPENDIX
639
P/S alarms
NC
alarm
No.
Message Description
5134
FSSB : OPEN READY TIME
OUT
The FSSB did not become ready to
open during initialization.
5135
FSSB : ERROR MODE
The FSSB entered an error mode.
5136
FSSB : NUMBER OF AMPS
IS SMALL
The number of amplifiers recognized
by the FSSB is insufficient, compared
with the number of controlled axes.
5137
FSSB : CONFIGURATION
ERROR
The FSSB detected a configuration
error.
5138
FSSB : AXIS SETTING NOT
COMPLETE
Axis setting has not been performed in
automatic setting mode. Perform axis
setting using the FSSB setting screen.
5139 FSSB : ERROR The servo system could not be
initialized normally. The cause may be
an optical cable failure or incorrect
connection with an amplifier and other
modules.
5197
FSSB : OPEN TIME OUT
The FSSB did not open when the CNC
had allowed the FSSB to open.
5198
FSSB : ID DATA NOT READ
The initial ID information for the
amplifier cannot be read because of a
failure in the temporary assignment.

Leave a Reply