641
Action: When automatic setting on the FSSB screen is not
performed, set all of parameter Nos. 1902, 1905, 1910
through 1919, 1936, and 1937 to 0 before starting manual
setting.
D The invalid amplifier/motor combination alarm (466) is issued.
Action: Check if the maximum current value of the amplifier read on
the ID screen matches the setting of parameter No. 2165.
Recheck the amplifier/motor combination.
Action: Initialize the servo parameters of each axis.
D When the power is turned off then back on after modifying parameter
No. 1902, the system alarm (920) is issued.
Action: Disconnect the optical cable of the CNC, then turn off then
on the power.
Set all of parameter Nos. 1902, 1905, 1910 through 1919,
1936, and 1937 to 0, then turn off then on the power, then
make an FSSB setting all over again.