Fanuc Power Mate i-D/H Maintenance Manual

H. FSSB STARTUP PROCEDURE/
MATERIALS
B63175EN/03
APPENDIX
642
The FSSB setting screen displays FSSBbased amplifier and axis
information, and allows amplifier and axis information to be set.
No display is possible with a combination of the DPL/MDI and its
operation package.
It cannot be used with the twopath control function of the Power Mate
iD.
1 Press function key
SYSTEM
.
2 Pressing the continuous menu key
several times displays
[FSSB].
3 Pressing soft key [FSSB] switches the screen display to the amplifier
setting screen (or the FSSB setting screen selected previously), and
displays the following soft keys:
[ AMP ][ AXIS ][ MAINT ][ ][ (OPRT) ]
There are three types of FSSB setting screens: the amplifier setting screen,
axis setting screen, and amplifier maintenance screen.
Pressing soft key [AMP] switches the screen display to the amplifier
setting screen.
Pressing soft key [AXIS] switches the screen display to the axis setting
screen.Pressing soft key [MAINT] switches the screen display to the
amplifier maintenance screen.
The amplifier setting screen displays slave information divided into
amplifier information and pulse module information.
(AMPLIFIER SETTING) O1000 N00001
NO.
1A1L α SVMHV 40AL 1 X
2A1M α SVM 12A 2 Y
3A2L β SVM 40A 3 Z
4A3L α SVM 20A 4 A
5A3M α SVM 40A 5 B
7A4L α SVU 240A 6 C
NO. PCB ID
6 M1 A 0000 DETECTOR(8AXES)
8 M2 B 12AB
>_
MDI **** *** *** 13:11:56
[ AMP ][ AXIS ][ MAINT ][ ][ (OPRT) ]
The amplifier setting screen displays the items below.
D NO.: Slave number
The serial numbers for to up to ten slaves (up to eight amplifiers and
up to two pulse modules) connected via the FSSB are displayed
sequentially. A younger number is assigned to a slave closer to the
CNC.
H.8
FSSB DATA DISPLAY
H.8.1
Amplifier Setting
Screen

Leave a Reply