Fanuc Power Mate i-D/H Maintenance Manual

B63175EN/03
H. FSSB STARTUP PROCEDURE/
MATERIALS
APPENDIX
643
D AMP: Amplifier type
Amplifier type information starts with the character A, which stands
for amplifier. The character A is followed by the ordinal number of
an amplifier counted from the amplifier closest to the CNC, then is
followed by a letter indicating which axis of the amplifier is used (L
for the first axis, and M for the second axis).
D AXIS NO: Controlled axis number
The controlled axis numbers set in parameter Nos. 1920 through 1929
are displayed.
When a value outside the range 1 to the maximum number of
controlled axes is set, 0 is displayed.
D NAME: Controlled axis name
The axis name set in the parameter No. 1020 corresponding to a
controlled axis number is displayed. When the controlled axis number
is 0, is displayed.
D As amplifier information, the following information items are
displayed:
S UNIT: Type of servo amplifier unit
S SERIES: Servo amplifier series
S CURRENT: Maximum current value
D As pulse module information, the information items below are
displayed.
S EXTRA
The character M, which stands for pulse module, is followed by
the ordinal number of a pulse module counted from the pulse
module closest to the CNC.
S TYPE
The type of a pulse module is displayed by a letter.
S PCB ID
The ID of a pulse module is displayed using four digits in
hexadecimal. For a separate detector module (8 axes),
DETECTOR (8AXES) is displayed after the pulse module ID. For
a separate detector module (4 axes), DETECTOR (4AXES) is
displayed after the pulse module ID.