1. DISPLAY AND OPERATION
41
Recorded data can be output to an input/output unit connected via a
reader/punch interface. An output record can be input from the
input/output unit.
Set the input/output unit to be used in setting parameters No. 0020 and
0100 to 0135.
To output the data, set a code in the ISO bit of a setting parameter (bit 1
of parameter No. 0020).
(1)Select EDIT mode.
(2)Press the
SYSTEM
key, then select the operation history display screen.
(3)Press the soft keys [(OPRT)],
, [PUNCH], and [EXEC] in this
order.
The data output to the FANUC Handy File is stored under file name
OPERATION HISTORY.
(1)Select EDIT mode.
(2)Press the
SYSTEM
key, then select the operation history display screen.
(3)Press the soft keys [(OPRT)],
, [READ], and [EXEC] in this
order.
1. MDI/soft key
2. Signal
3. Alarm
4. For extension (date or time)
5. MDI/soft key of path 2
6. Signal of path 2
7. Alarm of path 2
The header and recorded operation data are output, in this order. The
operation history data is divided into four parts by identifier words. Data
other than the identifier words depends on the type.
T0 : Header
T50 : MDI/soft key
T51 : Signal
T52 : Alarm
T53 : For extension (date or time)
T54 : MDI/soft key of path 2
T55 : Signal of path 2
T56 : Alarm of path 2
T(identifier word)
1.5.4
Inputting and
Outputting the
Operation History Data
D Output
D Input
D Output data format