The axis setting screen displays axis information.
(AXIS SETTING) O1000 N00001
M1 M2 Cs
1XA1L 0 00 01
2YA1M 1 0 1 0 0
3ZA2L 0 0 0 1 0
4AA3L 0 0 0 0 2
5BA3M 0 0 0 0 0
6CA4L 0 0 0 0 0
>_
MDI **** *** *** 13:11:56
[ AMP ][ AXIS ][ MAINT ][ ][ (OPRT) ]
The axis setting screen displays the items below.
D AXIS NO: Controlled axis number
The NC controlled axis numbers are displayed sequentially.
D NAME: Controlled axis name
D AMP: Type of amplifier connected to each axis
D M1: Connector number for pulse module 1
The connector number for pulse module 1 set in parameter No. 1931
is displayed.
D M2: Connector number for pulse module 2
The connector number for pulse module 2 set in parameter No. 1932
is displayed.
D 1DSP
The value set in bit 0 (1DSP) of parameter No. 1904 is displayed. The
value 1 is displayed for an axis (highspeed current loop axis) that
exclusively uses a DSP.
D TANDEM (M series only)
The value set in parameter No. 1934 is displayed. For a master axis
and slave axis used for tandem control, an odd number and a
subsequent even number are displayed.