Fanuc Power Mate i-D/H Maintenance Manual

FANUC Power Mate i - MODEL D/H
The parameter set supporting screen
function
TITLE
START UP (BASIC)
1001#0 INM 0
1002#1 DLZ 0
1004#1 ISC 0
1005#0 ZRN X 1
Y 1
Z 1
A 1
A MOVEMENT OPERATION EXCEPT FOR G28 IS
ISSUED BEFORE THE REF-POS. PERFORMED
PS224 ALARM IS CAUSED:0 / NOT CAUSED:1
Figure 1.4.3 (b) (BASIC) group screen
Each parameter setting
Confirm the setting of “Parameter write enable” on the setting screen.
Position the cursor to the parameter that is desired to set.
Input the data by numerical key and press the [INPUT] soft key or
key .
INPUT
[NO.SRH] [ INIT ] [G_INIT] [ ] [ INPUT]
Setting of standard value
The standard parameter value is input by soft key.
There are two methods of inputting the standard parameter value. One is to
input only for the parameter selected by cursor and another is to input for
all parameters of the group to which the parameters are belonged.
The standard value for parameter is recommended by FANUC, and the
standard value cannot be changed to peculiar data for user.
And on the usual parameter setting screen, the standard value can not be
set to the parameter.
EDIT
DATE DISIGNE
DESCRIPTION
DRAW
B-63175EN/03-8
SHEET
5/11
APPROV.
FANUC LTD
New design 030207
01