Fanuc Power Mate i-D/H Maintenance Manual

FANUC Power Mate i - MODEL D/H
The parameter set supporting screen
function
TITLE
(1) The setting of the standard value for each parameter
Position the cursor on the parameter that is desired to set standard
parameter value. Confirm that following soft key is displayed on the screen
and press the [INIT] soft key.
[NO.SRH] [ INIT ] [G_INIT] [ ] [ INPUT]
The standard parameter value is displayed on the input line and the
warning of “DO YOU SET INIT-VALUE ?” is displayed.
Press the [EXEC] soft key and then the standard parameter value is set.
[ ] [ ] [ ] [ CAN ] [ EXEC ]
To cancel the setting of the standard parameter value, press the [ CAN ]
soft key. If there is no standard parameter value for the parameter that is
selected by cursor and press the [ INIT ] soft key, the warning of “HERE IS
NO INIT-VALUE” is displayed.
(2) The setting of standard value for all parameters in the group
Confirm the following soft key is displayed and press the [ G_INIT ] soft
key.
[NO.SRH] [ INIT ] [G_INIT] [ ] [ INPUT]
The following message is displayed instead of help message.
“STANDARD PARAMETERS VALUE OF GROUP (BASIC) ARE SET”
The display of soft key is changed to the following and the warning of “DO
YOU SET INIT-VALUE?” is displayed.
[ ] [ ] [ ] [ CAN ] [ EXEC ]
By pressing the [EXEC] soft key, standard parameter value of selected
group is set.
In this case, it is necessary to take care when the standard parameter
value is set, because the standard parameter value is set automatically
without displaying the standard value on the input line.
In order to cancel to set the standard parameter value, press the [ CAN ]
soft key. For safety, set emergency stop state when the standard value is
set for all parameters in the group,.
Display of usual parameter setting screen
Press the return menu key , and quit the soft key of
parameter set supporting screen . Next press the continuous menu key
several times till the following soft key is displayed.
[PARAM] [DGNOS] [ PMC ] [SYSTEM] [(OPRT)]
Press the [PARAM] soft key, then the usual parameter setting screen is
displayed.
EDIT
DATE DISIGNE
DESCRIPTION
DRAW
B-63175EN/03-8
SHEET
6/11
APPROV.
FANUC LTD
New design 030207
01