Fanuc Power Mate i-D/H Maintenance Manual

FANUC Power Mate i - MODEL D/H
The parameter set supporting screen
function
TITLE
1.4.6 Parameter
#7
#6 #5 #4 #3 #2 #1 #0
CPR
3195
[Data type] Bit type
CPR By using the function key [SYSTEM], the parameter set supporting screen
0 :is not displayed.
1 :is displayed.
1.4.7 Necessary parameter list when start up
Menu item Group Parameter no.
(initial value)
Brief explanation
AXIS
SETTING
BASIC 1001#0
(Nothing)
Least command increment on the
linear axis
0:mm
1:inches
1002#1
(Nothing)
Function setting the reference
Position without dog
0:disabled
1:enabled(for all axes)
1004#1
(Nothing)
The least input increment and least
command increment are set
0:IS-B
1:IS-C
1005#0
(0)
(0)
(0)
(0)
(0)
(0)
(0)
(0)
A movement operation except for
G28 is issued before the
reference-point is not established.
PS224 alarm is
0:caused(standard)
1:not caused
1005#1
(Nothing)
Function for setting the reference
position without dogs
0:disabled(for each axes)
1: enabled(for each axes)
1006#0
(Nothing)
Setting linear or rotation axis
0:linear
1:rotation
1006#5
(Nothing)
The direction of reference position
return
0:positive
1:negative
1008#0
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
The roll-over function of a rotation
axis
0:invalid
1:valid(standard)
EDIT
DATE DISIGNE
DESCRIPTION
DRAW
B-63175EN/03-8
SHEET
8/11
APPROV.
FANUC LTD
New design 030207
01