Fanuc Power Mate i-D/H Maintenance Manual

FANUC Power Mate i - MODEL D/H
The parameter set supporting screen
function
TITLE
Menu item Group Parameter no. Brief explanation
AXIS
SETTING
COORDINATE
1240
(Nothing)
Coordinate value of the first
reference position on each axis in the
machine coordinate system
1241
(Nothing)
Coordinate value of the second
reference position on each axis in the
machine coordinate system
1260
(360000)
(360000)
(360000)
(360000)
(360000)
(360000)
(360000)
(360000)
Amount per one rotation of a rotation
axis
Standard:
360000(IS-B)
3600000(IS-C)
1320
(Nothing)
Coordinate value of stored stroke
check 1 in the positive direction for
each axis
1321
(Nothing)
Coordinate value of stored stroke
check 1 in the negative direction for
each axis
FEED
RATE
1401#6
(0)
Dry run for rapid traverse command
0:disabled(standard)
1:enabled
1410
(Nothing)
Dry run rate
1420
(Nothing)
Rapid traverse rate for each axis
1421
(Nothing)
F0 rate of rapid traverse override fo
r
each axis
1422
(Nothing)
Maximum cutting feedrate for all
axes
1423
(Nothing)
Feedrate in manual continuous feed
(jog feed) for each axis
1424
(Nothing)
Manual rapid traverse rate for each
axis
1425
(Nothing)
FL rate of the reference position
return for each axis
EDIT
DATE DISIGNE
DESCRIPTION
DRAW
B-63175EN/03-8
SHEET
10/11
APPROV.
FANUC LTD
New design 030207
01