Fanuc Power Mate i-D/H Maintenance Manual

FANUC Power Mate i - MODEL D/H
The parameter set supporting screen
function
EDIT
DATE DISIGNE
DESCRIPTION
TITLE
DRAW
B-63175EN/03-8
SHEET
11/11
APPROV.
FANUC LTD
New design 030207
01
Menu item Group Parameter no. Brief explanation
AXIS
SETTING
ACC./DEC. 1610#0
(Nothing)
Acceleration/deceleration in cutting
feed is
0:expontential
1:linear after interpolation
1620
(Nothing)
Time constant T or T1 used for linear
acc./dec. or bell-shaped acc./dec. in
rapid traverse for each axis
1622
(Nothing)
Time constant of exponential
acc./dec. or bell-shaped or linear
after interpolation in cutting feed
1624
(Nothing)
Time constant of exponential
acc./dec. or bell-shaped or linear
after interpolation, in jog feed
1625
(Nothing)
FL rate of exponential acc./dec. in
jog feed for each axis
MISCELLANY MIST 3017
(Nothing)
Output time of reset signal RST
3030
(3)
Allowable number of digits for the
M-code
Standard setting value:3
3701#1
(Nothing)
Only PMi-D
The serial interface for the spindle
0:used
1:not used
7110
(1)
Number of manual pulse generators
used
Standard setting value:1