3. Parameter
#7 #6 #5 #4 #3 #2 #1 #0
3194 SVI IDW
[Data type] Bit
IDW The editing of the servo information screen is
0:prohibited.
1:not prohibited.
SVI The servo information screen is
0:displayed.
1:not displayed.
#7 #6 #5 #4 #3 #2 #1 #0
1807 SWP
[Data type] Bit
SWP Operation in the warning state of the servo amplifier αi series (fan stop etc.) is
specified.
0:When the amplifier is warning state, alarm occurs.
An automatic operation stops, and the servo axis is decelerated and stops.
1:When the amplifier is warning state, alarm doesn’t occur.
An automatic operation is continued.
When change the alarm state from the warning state, the servo is
deactivated.
Caution
In case of setting this parameter to 1, please stop operation by
the single block stop etc. immediately by observing
SVWRN1-4 of the servo warning detail signal with the ladder
when the servo amplifier becomes warning satate.