Fanuc Power Mate i-D/H Maintenance Manual

B63175EN/03
1. DISPLAY AND OPERATION
51
(1)Press
SYSTEM
key.
(2)Press soft key [DGNOS], then a diagnostic screen is displayed.
(1)Press the
DGNOS
PARAM
key to select the diagnosis screen.
(2)When PMC data is displayed, operate <No.> Number <INPUT>
in turn.
> @0001 0
@0002 1
Following are display methods in the diagnostic screen of PMC data.
000 WAITING FOR FIN SIGNAL An auxiliary function is being
executed.
001 MOTION Travel command of cycle
operation is being executed.
002 DWELL DWELL Dwell is being
executed.
003 INPOSITION CHECK Inposition check is being done.
004 FEEDRATE OVERRIDE 0% Feedrate override is 0%.
005 INTERLOCK/START LOCK Interlock is input.
006 SPINDLE SPEED ARRIVAL CHECK Waiting for spindle speed
arrival signal.
007 WAITING FOR CHASER OPEN OR The unit is waiting for the chaser
CLOSE tool to be opened or closed.
010 PUNCHING Data is being output through
reader/puncher interface.
011 READING Data is being input through
reader/puncher interface.
013 JOG FEEDRATE OVERRIDE 0% Jog override is 0%.
014 WAITING FOR RESET, ESP,RRW OFF Power Mate i is in reset state.
015 EXTERNAL PROGRAM NUMBER SEARCH External Program Number
Search External program
number search is being done
016 BACKGROUND ACTIVE Background is being used.
008 DURING WAITING BY The system is in M code
WAITING M CODE based wait state. (Wait M
function)
1.7
DISPLAYING
DIAGNOSTIC PAGE
1.7.1
Displaying Diagnostic
Page
D CRT, PDP, Hand
operators panel, and
LCD with touch panel
D DPL/MDI
1.7.2
Contents Displayed
D Causes when the
machine does not travel
in spite of giving a
command