Fanuc Power Mate i-D/H Maintenance Manual

1. DISPLAY AND OPERATION
B63175EN/03
60
Detail
number
MeasureCause
Parameter
number
10053 2018#0 The scale reverse connection bit has
been set up for a linear motor.
The scale reverse connection bit cannot
be used for linear motors.
10062 2209#4 The amplifier in use does not support the
HC alarm avoidance function.
If you want to use this amplifier, reset the
function bit listed at the left to 0.
If you want to use the HC alarm avoid-
ance function, use an amplifier that sup-
ports it.
360 Cumulative command pulse count (NC)
DGN
[Data type] Twoword axis
[Unit of data] Detection unit
[Valid data range] 99999999 to 99999999
Indicates the cumulative count of movement commands distributed from
the CNC since the power was switched on.
361 Cumulative compensation pulse count (NC)
DGN
[Data type] Word axis
[Unit of data] Detection unit
[Valid data range] 32767 to 32767
Indicates the cumulative count of compensation pulses (backlash
compensation, pitch error compensation, etc.) distributed from the CNC
since the power was switched on.
362 Cumulative command pulse count (SV)
DGN
[Data type] Twoword axis
[Unit of data] Detection unit
[Valid data range] 99999999 to 99999999
Indicates the cumulative count of movement command and compensation
pulses received at the servo section since the power was switched on.
363 Cumulative feedback pulse count (SV)
DGN
[Data type] Twoword axis
[Unit of data] Detection unit
[Valid data range] 99999999 to 99999999
Indicates the cumulative count of position feedback pulses received from
the pulse coder by the servo section.