Fanuc Power Mate i-D/H Maintenance Manual

B63175EN/03
1. DISPLAY AND OPERATION
61
#7
0400
#6 #5 #4
SAI
#3 #2
SSR
#1
POS
#0
DGN
This data indicates the offset data received by the CNC while it is
calculating the machine coordinates.
SAI 0 : Spindle analog control is not used.
1 : Spindle analog control is used.
SSR 0 : Spindle serial control is not performed.
1 : Spindle serial control is performed.
POS A module required for spindle analog control is
0 : not mounted
1 : mounted
0401 Serial spindle alarm state
DGN
#7
SSA0408
#6 #5
SCA
#4
CME
#3
CER
#2
SNE
#1
FRE
#0
CRE
DGN
CRE: A CRC error occurred. (Warning)
FRE: A framing error occurred. (Warning)
SNE: The transmission/reception target is invalid.
CER: An error occurred during reception.
CME: No response was returned during automatic scanning.
SCA: A communication alarm occurred on the spindle amplifier side.
SSA: A system alarm occurred on the spindle amplifier side.
(These problems cause spindle alarm 749. Such problems are mainly
caused by noise, disconnection, or instantaneous poweroff).
#7
0409
#6 #5 #4 #3
SPE
#2 #1
S1E
#0
SHE
DGN
Refer to this diagnosis when alarm 750 has generated.
SPE In spindle serial control serial spindle parameters
0 : Satisfy start condition of spindle unit
1 : Do not satisfy start condition of spindle unit
S1E 0 : Spindle started normally in spindle serial control.
1 : Spindle did not start normally in spindle serial control.
SHE 0 : Serial communication unit is correct on Power Mate i side.
1 : An error occurred in serial communication unit on Power Mate i side
D Serial spindle