Fanuc Power Mate i-D/H Maintenance Manual

1. DISPLAY AND OPERATION
B63175EN/03
72
Function Operation
Function
key
Mode
SETTING
PWE=1
KEY
SW
Program clear f When the
power is on
_ CRT/MDI
DELETE
Path 1 side : DELETE and 1
At 2path control (with Power Mate iD2)
Path 2 side : DELETE and 2
LCD with touch panel
Turn on the power while holding down
the topright corner of the screen.
Display the IPL screen, then
DEL [SELECT] [YES] [EXIT]
[YES]
At 2path control (with Power Mate iD2)
Path 1 side:
DEL [SELECT] [YES]
1 [SELECT] [YES] [YES]
Path 2 side:
DEL [SELECT] [YES]
2 [SELECT] [YES] [YES]
Program under editing when the
power is off (PS101)
_ _
RESET
CAN
CRT/MDI
and
LCD with touch panel
SPCL CAN RESET
ENTER
Clearing a ladder program*
When the
power is on
CRT/MDI
X and O
LCD with touch panel
Turn on the power while holding down
the topright corner of the screen.
Display the IPL screen, then
X [SELECT] [YES]
O [SELECT] [YES] [YES]
PMC nonvolatile memory
When the
power is on
CRT/MDI
Z and O
LCD with touch panel
Turn on the power while holding down
the topright corner of the screen.
Display the IPL screen, then
Z [SELECT] [YES]
O [SELECT] [YES] [YES]
WARNING
1 After completion of ladder program input, the power must be turned on again because the
ladder program is in halt state.
2 This function clears no ladder program in FROM.
3 The operations with the LCD, PDP, detachable LCD/MDI, and handy operators panel are the
same as listed above. With the handy operators panel, however, some functions cannot be
used.