3
1
4
5
6
7
8
9
10
2
80
Clear
Function
KEY
SW
PWE
= 1
Mode
Function
key
Operation
Memory all At
INIT
MEMORY ALL CLEAR
clear
(Note)
power–
up
SYSTEM
operation
Path 1 side of twopath con-
trol
OTHERS
[KEY CODE1] 1
[KEY CODE1] CAN
Path 2 side of twopath con-
trol
OTHERS
[KEY CODE1] 2
[KEY CODE1] CAN
Parame-
ters/offset
At
power–
INIT
SYSTEM
MEMORY CLEAR
(PARAMETER, OFFSET)
up
operation
Path 1 side of twopath con-
trol
OTHERS
[KEY CODE1] 1
[KEY CODE1] PARAM
Path 2 side of twopath con-
trol
OTHERS
[KEY CODE1] 2
[KEY CODE1] PARAM
Program
clear
At
power–
INIT
SYSTEM
MEMORY CLEAR
(PROGRAM)
up
operation
Path 1 side of twopath con-
trol
OTHERS
[KEY CODE1] 1
[KEY CODE1] DELETE
Path 2 side of twopath con-
trol
OTHERS
[KEY CODE1] 2
[KEY CODE1] DELETE
Program
being
edited at
power
failure
(PS101)
[F2] + [Back Space]
Ladder At
power–
up
INIT
SYSTEM
operation
MEMORY CLEAR (PMC
LADDER)
PMC non-
volatile
memory
At
power–
up
INIT
SYSTEM
operation
MEMORY CLEAR (PMC
PARAMETER)
NOTE When memory all clear operation is performed, twopath control is
switched to onepath control.