Fanuc Power Mate i-D/H Operation Maintenance Handbook

5. CUSTOM MACRO
103
5.1 Types of Variables
Type of variable Variable number
Local variable #1 – #33
Common variable #100 – #199
#500 – #699
System variable (Note 2) #1000 – #9814
NOTE Details are shown in 5.2.
5.2 System Variable
Variable
number
Contents Purpose Series
#1000–#1015 Corresponds to UI000 to UI015
Interface input PM i–D/H
#1032 Unified input of UI000 to UO015
signal
#1100–#1115 Corresponds to UO000 to
UO015
Interface
output signal
PM i–D/H
#1132 Unified output of UO000 to
UO015
#1133 Unified output of UO100 to
UO131
#1200–#1959
#1991–#1995
PMC D/R area information Interface PM i–D/H
#3000 Alarm PM i–D/H
#3001 Clock 1 (unit: 1ms)
Clock PM i–D/H
#3002 Clock 2 (unit: 1 hour)
#3003 Control of single
block stop, wait
signal for FIN
PM i–D/H
#3004 Control of feed-
hold, feedrate
override, exact
stop check
PM i–D/H
#3005 Setting PM i–D/H
#3007 Mirror image check signal Status of
mikrror image
PM i–D/H
#3011 Year, month, day
Clock PM i–D/H
#3012 Hour, minute, second
#3901 No. of parts machined
No. of parts PM i–D/H
#3902 No. of parts required
#4001–#4022 G code (group 01–22)
Modal PM i–D/H
#4109 F code
information
#4111 H code
#4113 M code
#4114 Sequence number
#4115 Program number
#4119 S code (PM i–D/D2)
#4120 T code
#5001–#5008 1st axis block end position
to
8th axis block end position
Block end
position (Work-
piece coordi-
nate)
PM i–D/H

Leave a Reply