6.1 Displaying CNC Internal State
6.1.1 Procedure for displaying diagnostic screen
Display the CNC internal state as below:
Change by page change key
Input a diagnostic data
No. to be displayed.
[NO.SRH]
SYSTEM
[DGNOS]
6.1.2 Display of status in which command is not apparently
executed (No. 000 015)
No. Display Internal status when 1 is displayed
000 WATING FOR FIN
SIGNAL
M, S, T function is being executed
001 MOTION Move command in automatic operation is being
executed
002 DWELL Dwell is being executed
003 IN–POSITION
CHECK
In-position check is being performed
004 FEEDRATE OVER-
RIDE 0%
Override 0%
005 INTERLOCK/
START–LOCK
Interlock startlock is on.
006 SPINDLE SPEED
ARRIVAL CHECK
Waiting for spindle speed arrival signal to turn
on
007 WAITING FOR
CHASER OPEN OR
CLOSE
Waiting for the chaser tool to open or close
008 DURING WAITING
BY WAITING M
CODE
Waiting with an M code.
(Wait M function)
010 PUNCHING Data is being output via reader puncher inter-
face
011 READING Data is being input via reader puncher interface
013 JOG FEEDRATE
OVERRIDE 0%
Jog override 0%
014 WAITING FOR RE-
SET, ESP, RRW
OFF
One of the emergency stop, external reset, re-
set & rewind or MDI panel reset key is on.
015 EXTERNAL PRO-
GRAM NUMBER
SEARCH
External program number search is active.
016 BACKGROUND
ACTIVE
Background is being used.
6. STATUS DISPLAY BY SELFDIAGNOSTIC DISPLAY