Fanuc Power Mate i-D/H Operation Maintenance Handbook

6. STATUS DISPLAY BY SELFDIAGNOSTIC DISPLAY
111
6.1.3 Information indicating automatic operation stop, automatic
idle statuses (No. 020 025)
No. Display Internal status when 1 is displayed
020 CUT SPEED UP/
DOWN
Set when emergency stop turns on or when ser-
vo alarm occurs
021 RESET BUTTON
ON
Set when reset key turns on
022 RESET AND
REWIND ON
Reset and rewind turned on
023 EMERGENCY
STOP ON
Set when emergency stop turns on
024 RESET ON Set when external reset, emergency stop, reset
or reset & rewind key is on.
025 STOP MOTION OR
DWELL
A flag which stops pulse distribution. It is set to
1 in the following cases.
(1) External reset is set to on.
(2) Reset & rewind is set to on.
(3) Emergency stop is set to on.
(4) Feed hold is set to on.
(5) The MDI panel reset key turned on.
(6) Switched to the manual mode
(JOG/HANDLE/INC).
(7) Other alarm occurred.
(There is also an alarm which is not set.)
Causes for cycle start LED turned off
020 CUT SPEED UP/DOWN 1 0 0 0 1 0 0
021 RESET BUTTON ON 0 0 1 0 0 0 0
022 RESET AND REWIND ON 0 0 0 1 0 0 0
023 EMERGENCY STOP ON 1 0 0 0 0 0 0
024 RESET ON 1 1 1 1 0 0 0
025 STOP MOTION OR DWELL 1 1 1 1 1 1 0
Emergency stop signal input
External reset signal input
MDI reset button turned on
Reset & rewind input
Servo alarm generation
Changed to another mode or feed hold
Single block stop
6.1.4 TH alarm statuses (No. 030, 031)
No. Display Internal status when 1 is displayed
030 CHARACTER
NUMBER TH DATA
The position of the character which turned TH
alarm on is displayed in the number of charac-
ters from the beginning of the block at TH
alarm.
031 TH DATA Read code of character which turned TH alarm
on