Fanuc Power Mate i-D/H Operation Maintenance Handbook

3
1
4
5
6
7
8
9
10
2
116
No.
#7
#6 #5 #4 #3 #2 #1 #0
409
SPE S1E SHE
Refer to this diagnosis when alarm 750 has generated.
SPE In spindle serial control, serial spindle parameters
0: Satisfy start condition of spindle unit
1: Do not satisfy start condition of spindle unit
S1E 0: Spindle started normally in spindle serial control.
1: Spindle did not start normally in spindle serial control.
SHE 0: Serial communication module is correct on CNC side.
1: An error occurred in serial communication module on CNC side.
No.
410
Display of the load meter for the spindle (%)
No.
411
Display of the speed meter for the spindle (rpm)
The above DGN parameters (No. 414 to 416) are represented in units of
pulses. One pulse corresponds to an error of 360/4096 (degrees).
No.
417
Feedback information of spindle position coder
No.
418
Position error of spindle position loop mode
The above four DGN items (No. 417 to 420) directly display the data received
from the serial spindle control unit.
6.1.11 Rigid tapping display (No. 450–457)
No.
450
Spindle position error during rigid tapping
The position deviation of the spindle during rigid tapping is displayed in
detection units.
No.
451
Spindle distribution during rigid tapping
The number of pulses issued to the spindle during rigid tapping, is displayed
in detection units.
No.
454
Accumulated spindle distribution during rigid tapping
The cumulative number of pulses, issued to the spindle during rigid tapping,
is displayed in detection units.

Leave a Reply

Your email address will not be published. Required fields are marked *