6. STATUS DISPLAY BY SELFDIAGNOSTIC DISPLAY
121
6.2 Screen Display at Power On
(1) Slot configuration display
PCB modules mounted on the slots are displayed. The CRT displays
this screen when a hardware trouble or invalid leading of PCB has
occurred.
(a) Screen display
SLOT CONFIGURATION DISPLAY
0: 003E4000 0:
1: 30464202 1:
2: 00504303 2:
3: 3:
4: 4:
5: 5:
::
::
Slot No. (2ndary)
Module ID code, Software ID code, Logical No. (*1)
Slot No. (Primary)
*1) Module ID code of PCBs
ĘĘjjnn
Slot No. of CNC (Logical No.)
Module function (Software ID code)
Type of PCBs (Module ID code)
(b) Module ID code
ID
Name
DD Power Mate i base PCB
AA High–speed serial bus (HSSB) board
C4 or 95 FANUC I/O LinkII board
E3 PROFIBUS–DP slave board
FC PROFIBUS–DP master board
36 Ethernet board
EF or BF DeviceNet, slave board, master board
(c) Software ID code
40 : Basic function
5E : HSSB board
5F : Ethernet board
69 : PROFIBUS–DP slave board
6A : PROFIBUS–DP master board
6E : I/O LinkII board
70 : DeviceNet master board
71 or 79 : DeviceNet slave board