Fanuc Power Mate i-D/H Operation Maintenance Handbook

6. STATUS DISPLAY BY SELFDIAGNOSTIC DISPLAY
127
PM i–HPM i–DAddressSignal nameSymbol
+EDITA to
+EDITH
PMC/controlled–axis–
direction–specific
interlock signal
G462 f f
+J1 to +J8
Feed axis and
direction selection
signals
G100 f f
+
+J1O to +J4O
Software operator’s
panel signals (+J1 to
+J4)
F081#0,#2
,#4, #6
f f
+LM1 to +LM8
Stroke check external
setting signals
G110 f f
+MIT1 to +MIT8
Interlock signal for
each axis and
direction
G132 f f
+STEPn Device step signal G450 f
EDITA to
–EDITH
PMC/control–axis–dir
ection–specific
interlock signal
G463 f f
J1 to –J8
Feed axis and
direction selection
signals
G102 f f
J1O to –J4O
Software operator’s
panel signals (J1 to
–J4)
F081#1,#3
,#5, #7
f f
LM1 to –LM8
Stroke check external
setting signals
G112 f f
MIT1 to –MIT8
Interlock signal for
each axis and
direction
G134 f f
–STEPn Device step signal G451 f
ABTQSV
Servo axis abnormal
load detected signal
F090#0 f f
ABTSP1
Spindle abnormal load
detected signal
F090#1 f
ACT
Temporary interrupt
detection signal
G212#7 f f
AD00 to AD12,
ADSGN
Analog input signal
F206 to
F207
f f
AFL
Auxiliary function lock
signal
G005#6 f f
A
AL Alarm signal F001#0 f f
A
ALAPC APC alarm signal F251#0 f f
ALMA
Alarm signals (serial
spindle)
F045#0 f
ALOH
Over heat alarm
signal
F250#5 f f
ALOT
Over travel alarm
signal
F250#4 f f
ALPS P/S alarm signal F250#3 f f
ALPS1 P/S alarm 100 signal F250#0 f f
ALPS2 P/S alarm 000 signal F250#1 f f