Fanuc Power Mate i-D/H Operation Maintenance Handbook

7. HARDWARE
211
7.9.6 Setting in normal operation
In normal operation, the following can be set by using the
7–segment LED and pushbutton switch:
Explanation
D When the pushbutton switch is held down for about five seconds with the
rotary switch set to 0, 0 blinks at high speed on the 7segment LED. Then,
when the pushbutton switch is pressed again, primary selection mode ex-
plained below is entered.
D In primary selection mode, numbers corresponding to operations appear one
by one.
D When a desired number appears on the 7segment LED, press the pushbut-
ton switch. Then, the LED indication blinks at high speed. Pressing the
pushbutton switch again enters secondary selection mode.
D When the lowest level of each setting has been determined, the finally deter-
mined operation value stays indicated on the LED. (When the pushbutton
switch is pressed again, or an alarm is issued in this condition, the ordinary
LED indication state is restored.)
Primary Secondary Explanation
End of this operation
Reserved
Reserved
Uses the following package software:
Cancels the RS232C channel setting made by
the secondary selection explained below (opera-
tion 1 to 4).
D To cancel the DPL/MDI operation package (for
boot operation) setting made at power–up,
also select this number.
Uses the DPL/MDI operation package for
RS–232C channel 2.
D This setting is maintained even after power is
turned off. When the setting needs to be
cleared, set 0 which is explained above.
D Once this setting is made, boot operation by
the DPL/MDI operation package will be en-
abled at the next and subsequent power–up
operation. (For the operation method, refer to
the operators manual on the DPL/MDI opera-
tion package.)
Uses FAPT LADDERII for RS232C channel 2.
D This setting is maintained even after power is
turned off. When the setting needs to be
cleared, set 0 which is explained above.
Reserved
Reserved