Fanuc Power Mate i-D/H Operation Maintenance Handbook

3
1
4
5
6
7
8
9
10
2
216
1) Parameters for SETTING
Number
Contents Remarks
0000 For Setting
#0 TVC : TV check is not performed (0)/performed (1)
#1 ISO : Data output by EIA code (0)/by ISO code (1)
#2 INI : Input increment by mm (0)/by inch (1)
#5 SEQ : Automatic insertion of sequence No. is, not
performed (0)/performed (1)
PRM3216
0002 Parameter relating to reference position
#7 SJZ : For manual reference position return,
deceleration dogs are used when a reference
position is not established, and positioning is
performed when a reference position is
established (0)/deceleration dogs are used at
all times (1)
PRM
1005#3=1
0012 Parameter for axis detaching, mirror image <Axis>
#0 MIR : Setting of mirror image for each axis is OFF
(0)/ON (1)
#7 RMV : Detach of the each axis is not performed (0)/
performed (1)
PRM
1005#7
0020 Selection of channel for input/output devices
Setting 0 1 2 4 (Memory card
interface)
Common PRM0100
Output
format
PRM 0101 PRM 0111 PRM 0121
Specification
number
PRM 0102 PRM 0112 PRM 0122
Transfer
rate
PRM 0103 PRM 0113 PRM 0123
Transfer
method
Not set
Connector
number
JD42
6 : DNC1/Ethernet
(During DNC operation only)
7 : Memory card interface
(Touch panel side)
20 : Data input/output when the I/O Link with the Power Mate in
group 0 is used
to
35 : Data input/output when the I/O Link with the Power Mate in
group 15 is used

Leave a Reply