Fanuc Power Mate i-D/H Operation Maintenance Handbook

3
1
4
5
6
7
8
9
10
2
220
Number RemarksContents
0727 Ethernet parameter transfer/router IP address
selection
#0 TRN : Indicates whether Ethernet parameters were
received at the Ethernet board (1) / not (0).
#1 RIP : Indicates whether router IP address selection
is enabled (1) / disabled (0).
(*) Parameter Nos. 0704 to 0715 are valid only when the DPL/MDI
operation package is used as a display unit. When the CRT/MDI is
in use, the related information must be set on the “Ethernet
Parameter” screen.
6) Parameters of Power mate CNC manager
Number
Contents Remarks
0960 Power mate CNC manager
#0 SLV : When the power mate CNC manager is
selected, the screen displays: one slave
(0)/divided into four (1)
#1 MD1 : These parameters set a slave parameter
input/output destination.
#2 MD2 : These parameters set a slave parameter
input/output destination.
In either case, slave parameters are output in
program format.
#3 PMN : The power mate CNC manager function is:
enabled (0)/disabled (1)
#4 SPW (parameter write protection) :
Specifies whether to allow the power mate
CNC manger to always set slave parameters
(0) or use the PWE settings in the host CNC
as the values of slave parameters set by the
CNC manager (1).
#5 ASG : Specifies whether to check (0) or not to check
(1) that the number of bytes assigned to an
I/O address for input to or output from the β
amplifier is 16.
#6 2CH : Specifies whether the second of the two
channels connected to the I/O LINK is used
for communication (the first channel is used if
the β amplifier is not connected to the second
channel) (0) or the first channel is used for
communication (1).
When only one channel is connected to the
I/O LINK, the channel is always used for
communication.
0
MD2 MD1 Input/output destination
0 Part program storage
0
1 Memory card

Leave a Reply