Fanuc Power Mate i-D/H Operation Maintenance Handbook

8. PARAMETERS
223
Number RemarksContents
1020 Setting of name of each axis used for
programming
<Axis>
X : 88 Y : 89 Z : 90
A : 65 B : 66 C : 67
U : 85 V : 86 W : 87
1022 Setting of each axis in the basic coordinate
system
<Axis>
0 : Neither the basic three axes nor a parallel axis
1 : X axis of the basic three axes
2 : Y axis of the basic three axes
3 : Z axis of the basic three axes
5 : Axis parallel to the X axis
6 : Axis parallel to the Y axis
7 : Axis parallel to the Z axis
1023 Setting of axis number for each servo axis (1 to
No. of controlled axis)
<Axis>
8) Parameter for Coordinate system
Number
Contents Remarks
1201 Parameters for coordinates
#0 ZPR : When manual reference position return is
performed the automatic coordinate system is
not set (0)/set automatically (1)
#1 ZPI : The coordinate value of automatic coordinate
system is set PRM 1250 (0)/PRM 1250 & PRM
1251 (1)
PRM1250,
1251
1203 Parameter for reference position establishment
#0 ZRFCG : The reference position establishment
signals (ZRF1 to ZRF8) conform to the
conventional specifications (0)./The signals
conform to the new specifications (1).
A reference position establishment signal
turns on if a reference position is
established and turns off if the origin is lost.
It also turns off if the origin is lost
temporarily as while APC followup is in
progress or while the APC/SPC alarm is
being issued.
1240 Coordinate value of the first reference position
on each axis in the machine coordinate system
<Axis>
1241 Coordinate value of the second reference
position on each axis in the machine coordinate
system
<Axis>
1242 Coordinate value of the third reference position
on each axis in the machine coordinate system
<Axis>
1250 Coordinate value of the reference position used
when automatic coordinate system setting is
performed (mm input)
<Axis>
PRM
1201#1=0