11) Parameters of acceleration/deceleration control
Number
Contents Remarks
1601 Parameter relating to block overlap, inposition
check
#2 OVB : Cutting feed block overlap is not performed (0)/
is performed (1).
#4 RTO : Block overlap in rapid traverse is not performed
(0)/performed (1)
#5 NCI : Inposition check at deceleration is performed
(0)/not performed (1)
PRM 1722
1602 Acceleration/deceleration control
#0 FWB : Linear acceleration/deceleration before
interpolation is type A (0)/type B (1)
#3 BS2 : Types of post–interpolation
acceleration/deceleration related to cutting feed
used in the advanced feed forward mode
#6 LS2 :
0
BS2 LS2
Acceleration/deceleration
0 Exponential acceleration/
deceleration after interpola-
tion
0
1 Linear acceleration/decel-
eration after interpolation
1 0 Bell–shaped acceleration/
deceleration after interpola-
tion
1605 Time constant expansion function
#1 TCE : The time constant expansion function is not
used (0)/used (1).
Normal mode
Number of axes Valid range
1 to 2 0 to 32000
3 to 4 0 to 16000
5 to 8 0 to 8000
High–speed response mode
Number of axes Valid range
1 to 2 0 to 4000
3 to 4 0 to 2000
5 to 8 0 to 1000
1610 Acceleration/deceleration control <Axis>
#0 CTL :
#1 CTB :
#4 JGL : Acceleration/deceleration for manual feed is
exponential (0)/linear or bell-shaped (1).
0
CTBx CTBx
Acceleration/deceleration
0 Exponential acceleration/
deceleration
Parameter
0 1 Linear acceleration/decel-
eration after interpolation
1 0 Bell–shaped acceleration/
deceleration after interpola-
tion
PRM1622
PRM1622
PRM
1610#0,#1,
1624