Number RemarksContents
1762 Time constant of exponential acceleration/
deceleration in cutting feed in look-ahead feed
forward mode [msec]
<Axis>
1763 FL rate for exponential acceleration/
deceleration in cutting feed in look-ahead feed
forward mode [mm/min]
<Axis>
1768 Time constant of linear acceleration/
deceleration in cutting feed in look-ahead feed
forward mode [msec]
1770 Maximum machining speed during linear
acceleration/deceleration before interpolation
[mm/min]
Accelera-
tion/
decelera-
tion before
1771 Time needed until the machining speed
reaches the maximum machining speed during
acceleration/deceleration before interpolation
[msec]
tion before
interpola-
tion (look-
ahead
control
mode)
1784 Feedrate for overtravel alarm deceleration
during acceleration/deceleration before
interpolation (stroke check 1)
12) Parameters of servo
Number
Contents Remarks
1800 DRDY alarm, feed forward
#1 CVR : When velocity control ready signal VRDY is set
ON before position control ready signal PRDY
comes ON generated (0)/is not generated (1)
#2 OZR : If manual reference position return is
performed using the feed hold function when
there is a remaining distance to travel, a
miscellaneous function is being executed, a
dwell operation is being performed, or a
canned cycle is being executed, ALM091 is
issued (0)/not issued (1).
#3 FFR : The feed-forward function is enabled for cutting
only (0)/cutting and rapid traverse (1).
ALM 404