8. PARAMETERS
245
Number RemarksContents
3011 Acceptable width of M, S, and T function
completion signal (FIN) [ms]
3017 Output time of reset signal RST [16 ms]
3030 Allowable number of digits for the M code
(1 to 8)
3031 Allowable number of digits for the S code
(1 to 5)
PMi–D
3032 Allowable number of digits for the T code
(1 to 8)
14) Parameters of Display, and Edit
Number
Contents Remarks
3100 Parameter for MDI panel
#1 CEM : On screens such as the operation history
screen and help screen, keys on the MDI panel
are indicated in English (0)/with graphics
qualifying for CE marking (1)
3101 Display
#4 BGD : The display of a foreground program in the
background is disabled (0)/enabled (1).
3102 The selection of language used in the display
#0 JPN : Japanese
#1 GRM: German (Option)
#2 FRN : French (Option)
#4 ITA : Italian (Option)
#6 SPN : Spanish (Option)
When all
the bits are
set to 0,
English is
used.
3104 Parameters for position display
#0 MCN: The machine position display is not displayed
according to the unit of input (0)/displayed
according to the unit of input (1)
#3 PPD : When a coordinate system is set, the relative
position display is not preset (0)/preset (1)
#4 DRL : For displaying relative positions, tool length
compensation is considered (0)/not considered
(1)
#6 DAL : For displaying absolute positions, tool length
compensation is considered (0)/not considered
(1)
PRM
0000#2