8. PARAMETERS
251
Number RemarksContents
3403 Circular interpolation
#5 CIR : When R, I, J, and K are not specified for
circular interpolation, a linear movement is
made (0)/an alarm is issued (1).
#6 AD2 : Specification of the same address two or more
times in a block is enabled (0)/disabled (1)
ALM022
ALM5074
3404 Parameter for M function
#0 NOP : In program execution, only O, EOB, and N are
not ignored (0)/ignored (1).
#1 POL : For a command address allowing a decimal
point, omission of the decimal point is enabled
(0)/disabled (1)
#4 M30 : When M30 is read, the cursor returns to the
beginning of the program (0)/does not return to
the beginning of the program (1).
#5 M02 : The cursor returns to the beginning of the
program when M02 is read (0)/not return (1)
#6 EOR : When EOR(%) is read, an alarm is issued (0)/
not issued (1).
#7 M3B : The number of M code that can be specified in
one block is one (0)/three (PMiD) or five
(PMiH) (1)
ALM5073
ALM 5010
3406 G code clear PRM
3402#6=1
#1 C01 : Upon reset, the G codes in group 01 are
cleared (0)/not cleared (1).
#2 C02 : Upon reset, the G codes in group 02 are
cleared (0)/not cleared (1).
#3 C03 : Upon reset, the G codes in group 03 are
cleared (0)/not cleared (1).
#5 C05 : Upon reset, the G codes in group 05 are
cleared (0)/not cleared (1).
3407 G code clear PRM
3402#6=1
#0 C08 : Upon reset, the G codes in group 08 are
cleared (0)/not cleared (1).
#1 C09 : Upon reset, the G codes in group 09 are
cleared (0)/not cleared (1).
#5 C13 : Upon reset, the G codes in group 13 are
cleared (0)/not cleared (1).
3409 Clear F and H codes
#7 CFH : Specifies whether to clear (0) F and H codes or
not (1) when a reset occurs with parameter
CLR (bit 6 of No. 3402) = 1.
3410 Tolerance of arc radius [Setting unit]