Fanuc Power Mate i-D/H Operation Maintenance Handbook

3
1
4
5
6
7
8
9
10
2
252
Number RemarksContents
3411 M code preventing buffering 1
3412 M code preventing buffering 2
L L
3419 M code preventing buffering 9
3420 M code preventing buffering 10
16) Parameters for Pitch Error Compensation
Number
Contents Remarks
3620 Number of the pitch error compensation point
for the reference position for each axis
Valid data
range :
3621 Number of pitch error compensation points of
negative direction for each axis
0 - 1023
<Axis>
3622 Number of pitch error compensation points of
positive direction for each axis
3623 Magnification for pitch error compensation for
each axis (0–100)
<Axis>
3624 Interval between pitch error compensation
points for each axis [Setting unit]
<Axis>
17) Parameters for Spindle Control
Number
Contents Remarks
3701 Parameter for the number of connections in
serial spindle control
PMi–D
#1 ISI : Specifies whether the serial spindle interface is
used (0)/note used (1)
3702 Parameter for spindle orientation function
(O.S.S)
PMi–D
#2 OR1 : The stop position external-setting type
orientation function O.S.S is not used at the
spindle motor (0)/used (1)