Number RemarksContents
4015 Parameter of rotation direction of spindle
#0 ORIENT : The orientation function is not provided (0)/
provided (1)
#1 SPLDMT: The spindle load monitor function is
disabled (0)/enabled (1).
#2 SPDSW : The output switching function is not
provided (0)/provided (1)
Automatic
setting by
NC option,
Need not
changed
4016 One-rotation signal error detection function
#3 FFSMTH: The feed-forward smoothing function is
disabled (0)/enabled (1).
#6 RFCHK2: The position coder one-rotation signal error
detection function is disabled (0)/enabled
(1).
#7 RFCHK3: In spindle orientation or rigid tapping
reference position return mode, the position
coder one-rotation signal is not detected
again (0)/detected again (1).
4017 One-rotation signal error detection function
#2 RFCHK4 : During normal rotation, the position coder
one-rotation signal error detection function
is disabled (0)/enabled (1).
#7 NRROEV : With an orientation command from the
stop state, the shortcut function is
disabled (0)/enabled (1).
4019
#2 SSTTRQ : When the speed is 0, speed clamping is
disabled (0)/enabled (1).
#4 SDTCHG : In output switching, the function for
switching at a speed detection level or
lower operates independently of speed
detection (0)/at the speed detection level
or lower (1).
#7 PRLOAD : Automatic parameter setting is not
performed (0)/performed (1).
4020 Maximum motor speed [min
–1
]
4022 Speed arrival detection level [0.1%]
4023 Speed detection level [0.1%]
4024 Speed zero detection level [0.01%]
4025 Torque limit value [%]
4026 Load detection level 1 (LDT1 signal) [%]
4027 Load detection level 2 (LDT2 signal) [%]
4028 Output limit pattern
4029 Output limit value [%]
4030 Soft start (0)/stop time (1) [min
–1
/sec]
4031 Position coder method orientation stop position