8. PARAMETERS
281
Number RemarksContents
6205 Multi-step skip signal selection
#0 4S1 : For G31 P4/G04 Q4, the SKIP signal is not
used (0)/used (1).
#1 4S2 : For G31 P4/G04 Q4, the SKIP2 signal is not
used (0)/used (1).
#2 4S3 : For G31 P4/G04 Q4, the SKIP3 signal is not
used (0)/used (1).
#3 4S4 : For G31 P4/G04 Q4, the SKIP4 signal is not
used (0)/used (1).
6206 Multi-step skip signal selection
#0 DS1 : For G04, the SKIP signal is not used (0)/used
(1).
#1 DS2 : For G04, the SKIP2 signal is not used (0)/used
(1).
#2 DS3 : For G04, the SKIP3 signal is not used (0)/used
(1).
#3 DS4 : For G04, the SKIP4 signal is not used (0)/used
(1).
6209 Dwell skip
#0 DSK : The skip signal SKIPP from the PMC is not
effective (0)/effective (1) for the dwell skip
function.
6210 Size of buffer 1 (system variables 9000 to
9099)
PMi–H
6211 Size of buffer 2 (system variables 9100 to
9199)
PMi–H
6212 Size of buffer 3 (system variables 9200 to
9299)
PMi–H
6213 Size of buffer 4 (system variables 9300 to
9399)
PMi–H
6214 Size of buffer 5 (system variables 9400 to
9499)
PMi–H
6215 Size of buffer 6 (system variables 9500 to
9599)
PMi–H
6216 Size of buffer 7 (system variables 9600 to
9699)
PMi–H
6217 Size of buffer 8 (system variables 9700 to
9799)
PMi–H
6218 Buffer n (system variable 9n00 to 9n99) PMi–H
#n DIn : Specifies which to store, the absolute
coordinates (0) of the point specified with a
high–speed skip signal that is newly input / the
distance (1) from the point specified with the
previously input highspeed skip signal to the
point specified with the new highspeed skip
signal, to buffer n (system variable 9n00 to
9n99).