Fanuc Power Mate i-D/H Operation Maintenance Handbook

3
1
4
5
6
7
8
9
10
2
288
Number RemarksContents
7220 Name of generalpurpose switch on software
operator’s panel
PRM.No.7220 - No.7227 -SIGNAL 1 Sets the
character code
PRM.No.7228 - No.7235 -SIGNAL 2 Sets the
character code
PRM.No.7236 - No.7243 -SIGNAL 3 Sets the
character code
PRM.No.7244 - No.7251 -SIGNAL 4 Sets the
character code
PRM.No.7252 - No.7259 -SIGNAL 5 Sets the
character code
PRM.No.7260 - No.7267 -SIGNAL 6 Sets the
character code
PRM.No.7268 - No.7275 -SIGNAL 7 Sets the
character code
PRM.No.7276 - No.7283 -SIGNAL 8 Sets the
character code
7283 Name of generalpurpose switch on software
operator’s panel
34) Parameters for the external pulse input
Number
Contents Remarks
7670 Parameter for the external pulse input
#7 EXH : Axis selection by external pulse input. The
magnification is determined with the DI signal
(0)/parameter (1).
7681 Setting 1 for the ratio of an axis shift amount to
external pulses (M)
7682 Setting 2 for the ratio of an axis shift amount to
external pulses (N)
7701 Number of samplings for input pulse smoothing
#0 SM1 :
#1 SM2 :
#2 SM3 :
0
SM3 SM1 Number of samplings
04
SM2
0
01 10
00 21
10 160
1 140
10 41
11 41
01 81
7710 Setting of the axis number for axial movement
with external pulses