Fanuc Power Mate i-D/H Operation Maintenance Handbook

8. PARAMETERS
289
Number RemarksContents
7712 External pulse axis acceleration/deceleration
time constant (0 to 4000)
7713 External pulse axis acceleration/deceleration
FL rate
35) Parameters for axis control by PMC
Number Contents Remarks
8001 Parameter for axis control by PMC
#0 MLE : Machine lock for PMC control axis is valid (0)/
invalid (1)
#2 OVE : Dry run and override signals use the same
signal as CNC (0) / PMC particular signal (1)
#3 RDE : Dry run signal for rapid traverse command is
invalid (0) / valid (1)
#5 NCC : If a program command is specified for a
PMC–controlled axis, an alarm is issued if the
axis is controlled by the PMC, the CNC
command otherwise being valid (0)/an alarm is
always issued (1).
#6 AUX : The number of bytes for the code of an
auxiliary function (12H) command to be output
is 1 (0 to 255) (0)/2 (0 to 65535) (1)
#7 SKE : Skip signal uses same as CNC (0) / PMC
particular signal (1)
ALM139
SKIP/
ESKIP
8002 Parametr for axis control by PMC
#0 RPD : Rapid traverse rate of PMC control axis is set
by PRM 1420 (0)/specified by rapid traverse
rate (1)
#1 DWE: With IS-C, dwell is 1 msec (0)/0.1 msec (1).
#2 SUE : In external pulse synchronization,
acceleration/deceleration is enabled
(exponential) (0)/disabled (1).
#3 F10 : Sets the command unit of feedrate per minute
1mm/min (0)/10mm/min (1)
#4 PF1 : Set the the feedrate unit of feed
#5 PF2 :
#6 FR1 : Set the command unit of feedrate per revolution
#7 FR2 :
00
FR2 FR1 Metric input
0.0001 mm/rev
0
PF2 PF1 Feedrate unit
00 1/1
Inch input
0.000001 inch/rev
11
0 1 0.001 mm/rev 0.00001 inch/rev
1 0 0.01 mm/rev 0.0001 inch/rev
0
1 1/100
0 1/1001
1 1/10001