8. PARAMETERS
291
36) Parameters for the electronic cam function
Number
Contents Remarks
8081 Electronic cam function PMi–H
#0 ECM : The electronic cam function is not used
(0)/used (1).
#2 TYB : The electronic cam function conforms to
specification A (0)/B (1).
#3 EXD : Specifies whether to expand (1) the number of
cam figure data items for the electronic cam
function / not (0).
8082 Electronic cam PMi–H
#1 NCP : Specifies whether to use (0) phase matching
for the electronic cam function / not (1).
8086 Axis number of the cam shaft in the electronic
cam function
PMi–H
8087 Selection of the followup axis in the electronic
cam function
PMi–H
8088 Number of cam figure data items PMi–H
8090 Tolerance for followup axis speed difference
between the beginning and end of
synchronization in the electronic cam function
PMi–H
37) Parameters for twopath control
Number
Contents Remarks
8100 Twopath control PMi–D
#7 NWR: In twopath control, emergency stop is not
used (0)/used (1) in each path independently.
PRM
1803#3
38) Parameters for device
Number
Contents Remarks
8290 Device number PMi–H
8291 Device type PMi–H
8292 Magnification M of the device axis PMi–H
8294 Limit on the device PMi–H