Fanuc Power Mate i-D/H Operation Maintenance Handbook

8. PARAMETERS
299
Number RemarksContents
8732 High–speed skip signal PMi–H
#0 to #7 UP1 to UP7 : Enables (1) / disables (0) the
rising edge (0 1) of the
high–speed skip signal (bits 0 to
7 of X1003) as an interrupt for an
interrupt–type PMC or a
high–speed skip signal.
8733 High–speed skip signal PMi–H
#0 to #7 DN1 to DN7 : Enables (1) / disables (0) the
falling edge (1 0) of the
high–speed skip signal (bits 0 to
7 of X1003) as an interrupt for an
interrupt–type PMC or a
high–speed skip signal.
8745 Output address of the M code (high–speed
response function)
PMi–H
8746 Start address of the internal PMC relay used
with the compile function using a signal
(high–speed response function)
PMi–H
8760 Number of a program transferred to the Power
Mate by using the I/O Link
8781 Amount of DRAM used with the C executor or
FAPT PICTURE [64k Byte]
8790 Timing for executing an auxiliary macro
43) Maintenance
Number
Contents Remarks
8901 Maintenance
#0 FAN : A fan motor error is detected (0)/not detected
(1). (Use inhibited)