Fanuc Power Mate i-D/H Operation Maintenance Handbook

3
1
4
5
6
7
8
9
10
2
12
(2) Program checking screen
(a) Press soft key [CHECK].
RELABS
[][][][][]
(OPRT)
PROGRAM CHECK O2000 N00130
O0010 ;
G92 G90 X100. Y200. Z50. ;
G00 X0 Y0 Z0 ;
G01 Z250. F1000 ;
(ABSOLUTE) (DIST TO GO) G00 G94 G80
X 0.000 X 0.000 G17 G21
Y 0.000 Y 0.000 G90
Z 0.000 Z 0.000 G22 G49 G67
HM
T
FS
>_
MDI *** *** 16:05:59
Modal
information
Absolute or relative coordinates can be switched by software
Contents of the program.
(b) Operation
Soft key [(OPRT)]
[BG–EDT] ³ See the EDIT mode screen.
Program number
[O SRH]
[REWIND]
O
N
Sequence number
[NO.SRH]
N
Sequence number
[P TYPE]
N
Sequence number
[O TYPE]
(3) Screen displaying the contents of the program currently running
(a) Press soft key [CURRNT].
PRGRM
[][][][][]
CHECK CURRNT NEXT (OPRT)
PROGRAM O2000 N00130
>_ S 0 T0000
AUTO STRT *** 16:05:59
Modal
information
(CURRNT) (MODAL)
G01 X 17.500 G01 F 2000
G17 F 2000 G17
H 2 G91
G80 G22
G94
G21 H 2
G49 T
G80
S
Block data being processed
Data with a decimal point
corresponds to the absolute
command.
Data without a decimal point
corresponds to the incre-
mental command.
(b) Operation
Soft key [(OPRT)] [BG-EDT] See the EDIT mode screen.

Leave a Reply