9. ERROR CODE LIST
303
Number ContentsMessage
087 BUFFER OVERFLOW When entering data in the memory
by using Reader / Puncher interface,
though the read terminate command
is specified, input is not interrupted
after 10 characters read. I/O unit or
P.C.B. is defective.
090 REFERENCE RETURN
INCOMPLETE
The reference position return cannot
be performed normally because the
reference position return start point
is too close to the reference position
or the speed is too slow. Separate
the start point far enough from the
reference position, or specify a suffi-
ciently fast speed for reference posi-
tion return. Check the program con-
tents.
091 REFERENCE RETURN
INCOMPLETE
Manual reference position return
cannot be performed when automat-
ic operation is halted.
092 AXES NOT ON THE
REFERENCE POINT
The commanded axis by G27 (Refer-
ence position return check) did not
return to the reference position.
093 EXTERNAL SETTING
INCOMPLETE
The reference position external set-
ting cannot be performed because
the reference position external set-
ting signal is set to 1 in the following
status.
1) When the jog feed mode (JOG) is
not selected.
2) When the jog feed mode (JOG) is
selected, however the signal
ZRN is 0.
3) When the emergency stop signal
ESP is 0.
4) When the parameter APC
No.1815 bit 5 is 0.
(Caution)
With an absolute pulse coder, a ref-
erence point is set up even if the ref-
erence point external setting signal
is set to 1 during movement. In this
case, however, axis movement does
not stop even if the reference point is
set up.
100 PARAMETER WRITE
ENABLE
On the PARAMETER (SETTING)
screen, PWE (parameter writing en-
abled) is set to 1. Set it to 0, then re-
set the system.
101 PLEASE CLEAR MEMORY The power turned off while rewriting
the memory by program edit opera-
tion. If this alarm has occurred,
press <RESET> while pressing
<PROG>, and only the program be-
ing edited will be deleted.
Register the deleted program.
109 FORMAT ERROR IN G08 A value other than 0 or 1 was speci-
fied after P in the G08 code, or no val-
ue was specified.
110 DATA OVERFLOW The absolute value of fixed decimal
point display data exceeds the allow-
able range. Modify the program.