Fanuc Power Mate i-D/H Operation Maintenance Handbook

9. ERROR CODE LIST
315
Number ContentsMessage
410 SERVO ALARM: nTH AXIS
EXCESS ERROR
Either of the following errors oc-
curred.
1) For the nth axis, the positional
deviation while the operation
was stopped exceeded the value
set in parameter No. 1829.
2) For simple synchronous control,
the amount of compensation for
synchronization matching ex-
ceeded the value set in parame-
ter No. 8325.
This alarm is issued only for a
slave axis.
411 SERVO ALARM: nTH AXIS
EXCESS ERROR
The position deviation value when
the nth axis (axis 18) moves is
larger than the set value.
Refer to procedure of troubleshoot-
ing.
413 SERVO ALARM: nth AXIS
LSI OVERFLOW
The contents of the error register for
the nth axis (axis 18) exceeded
"2
31
power. This error usually oc-
curs as the result of an improperly
set parameters.
415 SERVO ALARM: nTH AXIS
EXCESS SHIFT
A speed higher than 511875 units/s
was attempted to be set in the n–th
axis (axis 18). This error occurs as
the result of improperly set CMR.